Gerson Rosenberg
All publications ( 54 )
  • Connell JM. Khalapyan T. Myers JL. Rosenberg G. Weiss WJ. Anatomic fit assessment for the Penn State pediatric ventricular assist device. 2007 Nov-Dec. ASAIO J. 53(6):687-91.
  • Lukic B. Zapanta CM. Khalapyan T. Connell J. Pae WE. Myers JL. Wilson RP. Undar A. Rosenberg G. Weiss WJ. The effect of left ventricular function and drive pressures on the filling and ejection of a pulsatile pediatric ventricular assist device in an acute animal model. 2007 May-Jun. ASAIO J. 53(3):379-84.
    National Heart, Lung, and Blood Institute
  • Connell JM. Khalapyan T. Al-Mondhiry HA. Wilson RP. Rosenberg G. Weiss WJ. Anticoagulation of juvenile sheep and goats with heparin, warfarin, and clopidogrel. 2007 Mar-Apr. ASAIO J. 53(2):229-37.
    National Heart, Lung, and Blood Institute
  • Connell JM. Pae WE. Rosenberg G. Comparison of LionHeart LVAD-implanted calves based on renal infarctions. 2007 Mar-Apr. ASAIO J. 53(2):147-51.
  • Undar A. Ji B. Lukic B. Zapanta CM. Kunselman AR. Reibson JD. Weiss WJ. Rosenberg G. Myers JL. Quantification of perfusion modes in terms of surplus hemodynamic energy levels in a simulated pediatric CPB model. 2006 Nov-Dec. ASAIO J. 52(6):712-7.
  • Undar A. Ji B. Lukic B. Zapanta CM. Kunselman AR. Reibson JD. Khalapyan T. Baer L. Weiss WJ. Rosenberg G. Myers JL. Comparison of hollow-fiber membrane oxygenators with different perfusion modes during normothermic and hypothermic CPB in a simulated neonatal model. 2006 Nov. Perfusion. 21(6):381-90.
  • Yamanaka H. Rosenberg G. Weiss WJ. Snyder AJ. Zapanta CM. Siedlecki CA. Short-term in vivo studies of surface thrombosis in a left ventricular assist system. 2006 May-Jun. ASAIO J. 52(3):257-65.
    National Heart, Lung, and Blood Institute
  • Zapanta CM. Griffith JW. Hess GD. Doxtater BJ. Khalapyan T. Pae WE. Rosenberg G. Microtextured materials for circulatory support devices: preliminary studies. 2006 Jan-Feb. ASAIO J. 52(1):17-23.
  • Undar A. Rosenberg G. Pierce WS. Cyran SE. Waldhausen JA. Myers JL. First International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion. 2005 September/October. ASAIO J. 51(5):iii.
  • Yamanaka H. Rosenberg G. Weiss WJ. Snyder AJ. Zapanta CM. Siedlecki CA. Multiscale analysis of surface thrombosis in vivo in a left ventricular assist system. 2005 Sep-Oct. ASAIO J. 51(5):567-77.
    National Heart, Lung, and Blood Institute
  • Rosenberg G. ASAIO - Building for the Future. 2005 Nov-Dec. ASAIO J. 51(6):v-vii.
  • Zapanta CM. Snyder AJ. Weiss WJ. Cleary TJ. Reibson JD. Rawhouser MA. Lewis JP. Pierce WS. Rosenberg G. Durability testing of a completely implantable electric total artificial heart. 2005 May-Jun. ASAIO J. 51(3):214-23.
    National Heart, Lung, and Blood Institute
  • Undar A. Rosenberg G. Myers JL. Part 1: principles of research on pulsatile and nonpulsatile perfusion during chronic support. 2005 May-Jun. ASAIO J. 51(3):303-4; author reply 305-8.
  • Undar A. Rosenberg G. Myers JL. Major factors in the controversy of pulsatile versus nonpulsatile flow during acute and chronic cardiac support. 2005 May-Jun. ASAIO J. 51(3):173-5.
  • Undar A. Zapanta CM. Reibson JD. Souba M. Lukic B. Weiss WJ. Snyder AJ. Kunselman AR. Pierce WS. Rosenberg G. Myers JL. Precise quantification of pressure flow waveforms of a pulsatile ventricular assist device. 2005 Jan-Feb. ASAIO J. 51(1):56-9.
  • Undar A. Rosenberg G. Myers JL. Impact of pulsatile flow on microcirculation. 2004 Nov-Dec. ASAIO J. 50(6):624-5.
  • Undar A. Rosenberg G. Myers JL. How should investigators compare different perfusion modes or different types of pulsatile flow during chronic support? 2004 Jul-Aug. ASAIO J. 50(4):401-2.
  • Donahue TL. Rosenberg G. Jacobs CR. Weiss WJ. Finite element analysis of stresses developed in blood sacs of a pusherplate blood pump. 2003 Feb. Comput Methods Biomech Biomed Engin. 6(1):7-15.
    National Heart, Lung, and Blood Institute
  • Mehta SM. Pae WE. Rosenberg G. Snyder AJ. Weiss WJ. Lewis JP. Frank DJ. Thompson JJ. Pierce WS. The LionHeart LVD-2000: a completely implanted left ventricular assist device for chronic circulatory support. 2001 Mar. Ann Thorac Surg. 71(3 Suppl):S156-61; discussion S183-4.
  • Hoenicke EM. Strange RG. Weiss WJ. Snyder AJ. Rawhouser MA. Rosenberg G. Prophet GA. Pae WE. Sun BC. Pierce WS. Modifications in surgical implantation of the Penn State electric total artificial heart. 2001 Mar. Ann Thorac Surg. 71(3 Suppl):S150-5; discussion S183-4.
    National Heart, Lung, and Blood Institute
  • Mehta SM. Weiss WJ. Snyder AJ. Prophet GA. Pae WE. Rosenberg G. Pierce WS. Testing of a 50 cc stroke volume completely implantable artificial heart: expanding chronic mechanical circulatory support to women, adolescents, and small stature men. 2000 Nov-Dec. ASAIO J. 46(6):779-82.
  • Bachmann C. Hugo G. Rosenberg G. Deutsch S. Fontaine A. Tarbell JM. Fluid dynamics of a pediatric ventricular assist device. 2000 May. Artif Organs. 24(5):362-72.
    National Heart, Lung, and Blood Institute
  • Liu Q. Runt J. Felder G. Rosenberg G. Snyder AJ. Weiss WJ. Lewis J. Werley T. In vivo and in vitro stability of modified poly(urethaneurea) blood sacs. 2000 Apr. J Biomater Appl. 14(4):349-66.
    National Heart, Lung, and Blood Institute
  • Weiss WJ. Rosenberg G. Snyder AJ. Pierce WS. Pae WE. Kuroda H. Rawhouser MA. Felder G. Reibson JD. Cleary TJ. Ford SK. Marlotte JA. Nazarian RA. Hicks DL. Steady state hemodynamic and energetic characterization of the Penn State/3M Health Care Total Artificial Heart. 1999 May-Jun. ASAIO J. 45(3):189-93.
    National Heart, Lung, and Blood Institute
  • Wu L. Weisberg DM. Runt J. Felder G. Snyder AJ. Rosenberg G. An investigation of the in vivo stability of poly(ether urethaneurea) blood sacs. 1999 Mar 15. J Biomed Mater Res. 44(4):371-80.
    National Heart, Lung, and Blood Institute
  • Kuroda H. Rosenberg G. Snyder AJ. Weiss WJ. Rawhouser M. Prophet GA. Stephenson E. Pae WJ. Pierce WS. Postoperative pulmonary complications in calves after implantation of an electric total artificial heart. 1998 Sep-Oct. ASAIO J. 44(5):M613-8.
  • Rosenberg G. Snyder AJ. Weiss WJ. Kusagawa H. Rawhouser MA. Prophet GA. Mehta S. Reibson JD. Cleary TJ. Dynamic in vitro and in vivo performance of a permanent total artificial heart. 1998 Jan. Artif Organs. 22(1):87-94.
    National Heart, Lung, and Blood Institute
  • Zapanta CM. Stinebring DR. Sneckenberger DS. Deutsch S. Geselowitz DB. Tarbell JM. Synder AJ. Rosenberg G. Weiss WJ. Pae WE. Pierce WS. In vivo observation of cavitation on prosthetic heart valves. 1996 Sep-Oct. ASAIO J. 42(5):M550-5.
    National Heart, Lung, and Blood Institute
  • Weiss WJ. Rosenberg G. Snyder AJ. Rawhouser M. Pierce WS. Kusagawa H. Mehta S. Prophet GA. Marlotte JA. Nazarian RA. Ford SK. Hicks DL. Recent improvements in a completely implanted total artificial heart. 1996 Sep-Oct. ASAIO J. 42(5):M342-6.
    National Heart, Lung, and Blood Institute
  • Ducko CT. McGregor ML. Rosenberg G. Pierce WS. The effect of valve type and drive line dP/dt on hemolysis in the pneumatic ventricular assist device. 1994 Jun. Artif Organs. 18(6):454-60.
    National Heart, Lung, and Blood Institute
  • Sapirstein JS. Pae WE. Rosenberg G. Pierce WS. The development of permanent circulatory support systems. 1994 Jul. Semin Thorac Cardiovasc Surg. 6(3):188-94.
    National Heart, Lung, and Blood Institute
  • Speedling EJ. Nizza AA. Eichhorn S. Rosenberg G. Schnepf P. The consumer survey review process: a pathway to quality. 1993 Oct. Mt Sinai J Med. 60(5):399-404.
  • Pierce WS. Snyder AJ. Rosenberg G. Weiss WJ. Pae WE. Waldhausen JA. A long-term ventricular assist system. 1993 Mar. J Thorac Cardiovasc Surg. 105(3):520-4.
    National Heart, Lung, and Blood Institute
  • Lamson TC. Rosenberg G. Geselowitz DB. Deutsch S. Stinebring DR. Frangos JA. Tarbell JM. Relative blood damage in the three phases of a prosthetic heart valve flow cycle. 1993 Jul-Sep. ASAIO J. 39(3):M626-33.
    National Heart, Lung, and Blood Institute
  • Weiss WJ. Rosenberg G. Snyder AJ. Donachy J. Reibson J. Kawaguchi O. Sapirstein JS. Pae WE. Pierce WS. A completely implanted left ventricular assist device. Chronic in vivo testing. 1993 Jul-Sep. ASAIO J. 39(3):M427-32.
    National Heart, Lung, and Blood Institute
  • Reibson JD. Rosenberg G. Snyder AJ. Cleary TJ. Donachy JH. Felder G. Pierce WS. An annular compliance chamber for the Pennsylvania State University electric total artificial heart. 1993 Jul-Sep. ASAIO J. 39(3):M415-8.
  • Snyder AJ. Rosenberg G. Weiss WJ. Ford SK. Nazarian RA. Hicks DL. Marlotte JA. Kawaguchi O. Prophet GA. Sapirstein JS. et al. In vivo testing of a completely implanted total artificial heart system. 1993 Jul-Sep. ASAIO J. 39(3):M177-84.
    National Heart, Lung, and Blood Institute
  • Snyder AJ. Rosenberg G. Reibson J. Donachy JH. Prophet GA. Arenas J. Daily B. McGary S. Kawaguchi O. Quinn R. et al. An electrically powered total artificial heart. Over 1 year survival in the calf. 1992 Jul-Sep. ASAIO J. 38(3):M707-12.
    National Heart, Lung, and Blood Institute
  • al-Mondhiry H. Pae WE. Rosenberg G. Pierce WS. Hematologic and hemostatic complications associated with long-term use of total artificial heart: clinical and experimental observations. 1992 Feb. Artif Organs. 16(1):83-9.
    National Heart, Lung, and Blood Institute
  • Snyder AJ. Rosenberg G. Pierce WS. Noninvasive control of cardiac output for alternately ejecting dual-pusherplate pumps. 1992 Apr. Artif Organs. 16(2):189-94.
    National Heart, Lung, and Blood Institute
  • Snyder A. Rosenberg G. Weiss W. Pierce W. Pae W. Marlotte J. Nazarian R. Ford S. A completely implantable total artificial heart system. 1991 Jul-Sep. ASAIO Trans. 37(3):M237-8.
  • Lamson TC. Stinebring DR. Deutsch S. Rosenberg G. Tarbell JM. Real-time in vitro observation of cavitation in a prosthetic heart valve. 1991 Jul-Sep. ASAIO Trans. 37(3):M351-3.
  • Pierce WS. Rosenberg G. Snyder AJ. Pae WE. Donachy JH. Waldhausen JA. An electric artificial heart for clinical use. 1990 Sep. Ann Surg. 212(3):339-43; discussion 343-4.
    National Heart, Lung, and Blood Institute
  • Weiss WJ. Rosenberg G. Snyder AJ. Cleary TJ. Gaumond RP. Geselowitz DB. Pierce WS. Permanent circulatory support systems at the Pennsylvania State University. 1990 Feb. IEEE Trans Biomed Eng. 37(2):138-45.
    National Heart, Lung, and Blood Institute
  • Jurmann MJ. Rosenberg G. Snyder AJ. Weiss W. Donachy JH. Pierce WS. In vivo determinants of energy consumption in electric motor driven artificial hearts. 1989 Jul-Sep. ASAIO Trans. 35(3):745-7.
    National Heart, Lung, and Blood Institute
  • Weiss WJ. Rosenberg G. Snyder AJ. Pae WE. Richenbacher WE. Pierce WS. In vivo performance of a transcutaneous energy transmission system with the Penn State motor driven ventricular assist device. 1989 Jul-Sep. ASAIO Trans. 35(3):284-8.
    National Heart, Lung, and Blood Institute
  • al-Mondhiry H. Pae W. Rosenberg G. Pierce W. Hematologic abnormalities and thromboembolic complications in calves implanted with pneumatic artificial hearts. Long-term studies and autopsy findings. 1989 Jul-Sep. ASAIO Trans. 35(3):238-41.
    National Heart, Lung, and Blood Institute
  • Davis PK. Rosenberg G. Snyder AJ. Pierce WS. Current status of permanent total artificial hearts. 1989 Jan. Ann Thorac Surg. 47(1):172-8.
  • Baldwin JT. Tarbell JM. Deutsch S. Geselowitz DB. Rosenberg G. Hot-film wall shear probe measurements inside a ventricular assist device. 1988 Nov. J Biomech Eng. 110(4):326-33.
    Public Health Service
    National Heart, Lung, and Blood Institute
  • Tsach U. Geselowitz DB. Sinha A. Tirinato J. Hsu HK. Rosenberg G. Pierce WS. Minimum power consumption of the electric ventricular assist device through the design of an optimal output controller. 1987 Jul-Sep. ASAIO Trans. 33(3):714-9.
  • Aufiero TX. Magovern JA. Rosenberg G. Pae WE. Donachy JH. Pierce WS. Long-term survival with a pneumatic artificial heart. 1987 Jul-Sep. ASAIO Trans. 33(3):157-61.
  • Pae WE. Rosenberg G. Pierce WS. Experimental and clinical experience with the Pennsylvania State University total artificial heart. 1987 Jul-Sep. Life Support Syst. 5(3):259-65.
  • Oaks TE. Pae WE. Rosenberg G. Pennock JL. Pierce WS. The use of a paracorporeal ventricular assist device as a bridge to cardiac transplantation. 1987 Jul-Sep. ASAIO Trans. 33(3):408-12.
  • Pierce WS. Donachy JH. Landis DL. Brighton JA. Rosenberg G. Migliore JJ. Prophet GA. White WJ. Waldhausen JA. Prolonged mechanical support of the left ventricle. 1978 Sep. Circulation. 58(3 Pt 2):I133-46.
    National Heart, Lung, and Blood Institute